  2. Eliwell Controls Programming Flow Charts & Parameters General - Installation & setup suggestions page 3 Adverse Condition Protection page 32 Programming & Flowcharts - EWPC901T/AR Single step thermostat. Page 4 EWPC902T/R/P Single step thermostat. Page 6 EWPC905T Two step/neutral zone thermostat page 8 EWTR910T Single step thermostat.

Datasheet

Extracted Text

Buy New or Surplus SCHNEIDER ELECTRIC EWPC-901/T ( DISCONTINUED BY MANUFACTURER, TEMPERATURE CONTROLLER, DIGITAL DISPLAY, W/ SENSOR ) parts. Radwell also repairs SCHNEIDER ELECTRIC EWPC-901/T. Buy the ELIWELL EWPC-901/T from Elite.Parts after requesting a quote. Call us at +1 (972) 476-1899.

Manual

EWPC 907temperature controller with dual outputGENERAL DESCRIPTIONsetting, push the “SET” plus the “UP” (orThe EWPC 907 is a temperature controller “DOWN”).with dual output, acting either indepen- The system will automatically return to itsdently or dependently (2-stage); the prima- normal operating mode a few seconds af-WHAT IT ISry output provides field selectable ON/OFF, ter the programming procedure is com-The EWPC 907 is a temperature PD or PID and SOFT START control. pleted or interrupted.controller with dual output, acting The front keypad of these controllers offersDESCRIPTION OF PARAMETERSeither independently or dependently several alpha-numeric menu prompts to(2-stage); the primary output pro- configure the controller for each specific Any parameter which does not apply to avides field selectable ON/OFF, PD application (see further). particular instrument version or configura-or PID and SOFT START control. The EWPC 907 is supplied in the popular tion is automatically removed from the pro-“32x74” ELIWELL housing. gramming menu.E.g.: a control for Thermocouple input willFRONT KEYPADnot offer parameters “Lci” and “Hci”.HOW IT IS MADESET: pushed once the setpoint 1 value will d1: differential 1.• Housing: black ABS plastic, au- be displayed for 3 seconds (Led “I” blinks). Activated only in ON/OFF control mode.toestinguish. Pushed once again within 3 seconds the Must be set with negative (-) value for heat-• Dimensions: front 74x32 mm setpoint 2 value will be displayed (Led “II” ing applications. (2.913x1.260'), depth 67 mm blinks). The setpoint can be changed with d2: differential 2.(2.637') the “UP” or “DOWN” button. The switching differential (hysteresis) set-• Mounting: flush panel mount with UP: used to increase the setpoint value, as point 2 must be set with positive valuemounting bracket well as the parameter when in program- (make on rise) or with negative value (make• Protection: the instrument front- ming. When held down for a few seconds, on fall). See parameter “HC2”.panel is waterproof IP65; an op- the change rate accelerates. LS1: Lower Set (limit) 1.tional snap-on cover can be DOWN: used to decrease the setpoint val- This is the lower limit below which the usersupplied to provide additional pro- ue, as well as the parameter when in pro- cannot change the setpoint 1; normally settection of the rear terminal block gramming. When held down for a few at the lowest value recommended for the• Connections: screw terminal seconds, the change rate accelerates. sensor.2block (2.5 mm ; one wire each ter- Led “I”: status light of output 1. LS2: Lower Set (limit) 2.minal only, in compliance with Blinks when in setpoint 1 display/change This is the lower limit below which the userVDE norms) mode or during programming. cannot change the setpoint 2; normally set• Display: 12.5 mm LED (0.50'). Led “II”: status light of output 2. at the lowest value recommended for the• Push buttons: located on front Blinks when in setpoint 2 display/change sensor.panel. mode. HS1: Higher Set (limit) 1.• Outputs: two (2) SPST relays 8(3)A Similar to “LS1”, however setting an upper250V AC PARAMETER PROGRAMMING limit for the setpoint 1.• Auxiliary output: 12 Vdc/60 mA Programming is easily accessed by hold- HS2: Higher Set (limit) 2.(for transducer power supply, e.g. ing the “SET” button down for more than 4 Similar to “LS2”, however setting an upperhumidity sensor, pressure trans- seconds; the first parameter is displayed limit for the setpoint 2.ducer, etc.) while the status light Led “I” remains blink- Pb: Proportional band.• Inputs (depending on model): ing during the programming period. This value, expressed in degrees, deter-PTC / RTD (Ni100, Pt100) / Other parameters are accessed with the mines the band-width around the setpointTC (J, K) / 4…20 mA (Ri = 41 Ω) “UP” and “DOWN” button. With the “SET” within which the instrument provides pro-• Resolution: 1 °C (°F) or 0.1 °C (°F). button, the actual setting of each parame- portional control. See also “PROPOR-The right-most digit can also be ter is displayed. To change a parameter TIONAL CONTROL”.set to read-out in 0 or 5 only, or inall 10 digits• Accuracy: better than 0,5% of fullscale• Power supply (depending on mod-el): 12 Vac/dc or 24 Vac/dcDEFAULT SETTINGS - STANDARD MODELS of “0” disables this function.dSt: dynamic Set time.Parameter Description Range Default UnitTime value between two successive dy-d1 differential 1 –1 / min –1 °C / °Fnamic setpoint increases.Lci: Lower current input.d2 differential 2 min / max 1 (C) / –1 (H) °C / °FRead-out corresponding to the “low endLS1 Lower Set limit 1 min / max min °C / °Fscale” input signal of 4 mA; only for mod-LS2 Lower Set limit 2 min / max min °C / °F els with current input.Hci: Higher current input. HS1 Higher Set limit 1 min / max max °C / °FRead-out corresponding to the “high endHS2 Higher Set limit 2 min / max max °C / °Fscale” of 20 mA; only for models with cur-Pb Proportional band 0.1 (1) / max 40 °C / °F rent input.CAL: CALibration.It Integral time 0 / 999 300 secondsThis offers an adjustment up or down ofdt derivative time 0 / 999 50 secondsthe read-out, if needed. Factory set at “0”.Ft: Function type. Sr Sampling rate 1 / 10 3 secondsControl mode selection (only for output 1;rSt manual reSet min / max 0 °C / °Foutput 2 is always ON/OFF).Ar Anti reset wind-up band 0 / max 20 °C / °Fon = ON/OFF;nr = not applicable;od output delay 0 / 500 0 secondsPi = PID.Ct Cycle time 1 / 500 25 secondsPSE: Probe SElection.drb dynamic restart band 0 / max 20 °C / °FInput type (for RTD or Thermocouplesonly).dSi dynamic Set increment 0 / max 10 °C / °FRTD models: Ni = Ni100; Pt = Pt100.dSt dynamic Set time 1 / 999 120 secondsT/C models: Fe = TcJ; Cr = TcK.Lci Lower current input min / max min °C / °FOCO: Output COnnection.Setpoint dependency.Hci Higher current input min / max max °C / °Fdi = setpoint 2 dependent on setpoint 1CAL CALibration min / max 0 °C / °F(for 2-stage control;Ft Function type on / Pi Pi flagin = setpoint 2 independent from setpoint1.PSE Probe SElection Ni / Pt / Fe / Cr / /HC2: Heating / Cooling (output) 2.OCO Output COnnection di / in in flagRelay switch function output 2.HC2 Heating / Cooling output 2 H / C H flagH = Heating;C = Cooling.rP1 relay Protection 1 ro / rc ro flagrP1: relay Protection 1. rP2 relay Protection 2 ro / rc ro flagDetermines the status of the relay in caseLF1 Led Function 1 di / in di flagof sensor defect. Factory set at “ro”.ro = relay open; rc = relay closedLF2 Led Function 2 di / in di flagrP2: relay Protection 2.dP decimal Point on / oF oF flagSame as “rP1”.hdd half digit display n / y n flag LF1: Led Function 1. Determines whether the status light is ONtAb tAble of parameters / / /or OFF in relation to output 1. di = direct = light ON when output 1 is en-It: Integral time. This is the half-band (on either side of the ergized;The higher this setting, the “smoother” the setpoint) in which the integral action takes in = reverse = light OFF when output 1 isintegral action. A setting of “0” completely place. The higher this setting, the stronger energized.eliminates the integral function and the integral action. Recommended initial LF2: Led Function 2. changes the controller from PID to PD setting: half of the value of parameter “Pb”. Same as “LF1”.(output 1). See also “PROPORTIONAL od: output delay. dP: decimal Point.CONTROL”. This provides a delay selection for the out- Choose whether the resolution is requireddt: derivative time. puts in applications where noise may with or without decimal point.The effect of the derivative action is in di- cause brief erroneous signals from the oF = without decimal point;rect proportion to this time setting. sensor to the controller. Factory set at “0”. on = with decimal point.See also “PROPORTIONAL CONTROL”. Ct: Cycle time. NOTES: (a) the decimal point of modelsSr: Sampling rate. This is the total time of one ONOFF cycle with current or voltage input is shifted: theTime between two successive read-outs, of the relay during the proportional action. actual value of parameters “Lci” and “Hci”for the computation of the derivative. A low See “PROPORTIONAL CONTROL”. must be multiplied by 10; (b) on all ver-setting increases the response time, but drb: dynamic restart band. sions, if a unit is changed from withoutalso the sensitivity to noise. This is a “soft start” function; when the decimal point to with decimal point, all pa-Recommended setting is from 1 to 3. temperature goes beyond this “restart rameter values expressed in degrees willrSt: manual reSet. band” (on either side of the setpoint), an- automatically be divided by 10, includingThis allows the proportional band to be other soft start cycle is initiated. The value the setpoint (c) the decimal point selectionmoved up or down. This parameter is ex- of this parameter represents half of the to- is not available on models for thermocou-pressed in degrees and must be set at a tal band; see also “SOFT START”. ple input.value opposite and corresponding to the dSi: dynamic Set increment. hdd: half digit display.noticed error. This represents the dynamic increase of The right-most digit can be set to read-outAr: Anti-reset wind-up band. the setpoint; see “SOFT START”. A setting in 0 or 5 only, or in all 10 digits.EWPC 907 7/2000 ing 2CONNECTIONS and fasten with the U-bracket suppliedwith the unit.The ambient temperature around the in-strument should be kept between –5 and65 °C (23…149 °F). Select a location which will not be subject8 9 10 8 9 10 8 9 10EWPC 907to high humidity or condensation and allowsome ventilation to provide cooling to theinstrument.PTC Pt100 / Ni100 Pt100 / Ni1003 wires 2 wiresELECTRICAL WIRING1 2 3 4 6 7 8 9 10The instrument is equipped with an internal8 9 10 8 9 10 8 9 10screw terminal block suitable for max22.5 mm wiring (one wire each terminal+ –load 1 load 2only, in compliance with VDE norms).TcJ / TcK EWHS 31 4…20 mA inputMake sure that the power supply corre-sponds with the rating shown on the in-POWER SUPPLYstrument, i.e. 12 Vac/dc or 24 Vac/dc.Refer to the instrument label for the applic-able terminals to be used for the sensorcable; separate the wiring of the input sig-hdd = n : e.g. 070, 071, 072 etc. (if with- culation of the deviation values. nals from those of the power supply andout decimal point) or 70.0, 70.1, 70.2 etc. As a result: switched output wiring.(if with decimal point); a) an increase in the proportional band The relay output contacts are voltage freehdd = y : e.g. 070, 075, 080, etc. (if with- width reduces the temperature swing, but and independent; do not exceed the resis-out decimal point) or 70.0, 70.5, 71,0, etc. increases the shift in stable system tem- tive rating of 8 Amp at 250 Vac. For larger(if with decimal point). perature; loads, please use an external contactor ortAb: tAble of parameters. b) an excessive reduction of the propor- relay.This shows the configuration of the para- tional band width reduces deviation, butERROR ANNOUNCIATIONmeters as set in the factory; can not be will also make the system less stable; modified (for factory identification and di- c) an increase in the derivative time re- Any sensor input defect will be displayedagnostic purposes only). duces temperature swings when the sys- as follows: “---” in case of shorted sensor;tem has become stable, but may cause “EEE” in case of sensor break, or sensorPROPORTIONAL CONTROL wider temperature swings and increased absence. The “EEE” error message alsoIn the event that the factory set parameter deviation from setpoint; appears in the event of ovverrange or un-values in a PID temperature controller do d) an increase in the integral time reduces derrange of the system temperature.not give optimum results, the following the deviation between setpoint and system It is recommended to doublecheck thesteps may be followed to enhance the op- value when system has become stable; sensor wiring before diagnosing a probeeration for each specific application: e) a weak integral action always has a tem- as defective.» set the controller for ON/OFF control perature deviation which, in general, canmode with parameter “Ft” (Ft = “on”); be eliminated by reducing the proportional TECHNICAL DATA» select a value for setpoint 1 which will band width and by increasing first of all the Housing: black ABS plastic, autoestin-keep the temperature swing within accept- derivative action, then the integral action. guish.able limits, for example 10% below the Dimensions: front 74x32 mmSOFT START (RAMP-TO-SETPOINT)normal operating temperature; (2.913x1.260'), depth 67 mm (2.637').» set the switching differential (“d1”) at 3% The SOFT START feature is available on Mounting: flush panel mount with mount-of the setpoint 1 temperature; output 1 only. ing bracket.» start the system and wait for the temper- This function provides automatically a pro- Protection: the instrument frontpanel isature swings to become constant; gressive (ramped) increase of the setpoint waterproof IP65; an optional snap-on cov-» check the process temperature (use a value starting from the value of Ta (ambient er can be supplied to provide additionaldata recorder if possible) at regular inter- temperature at start-up) up to the actually protection of the rear terminal block.vals; determine the time between two suc- selected setpoint temperature (see dia- Connections: screw terminal block2cessive temperature peaks (Tu) as well as gram on the right), thus eliminating any (2.5mm ; one wire each terminal only, inthe total temperature swing (dT; see dia- possible temperature “overshooting”. compliance with VDE norms).gram on the right). The following parameters determine this Display: 12.5 mm LED (0.50').Parameters “Pb”, “It”, “dt” and “Ct” can function: Push buttons: located on front panel.now be calculated as follows: - “drb”, half of the band width around set- Data storage: non-volatile EEPROM“Pb”=2xdT ; “It”=Tu/2 ; “dt”=Tu/8 ; point, outside of which the ramping of the memory.“Ct”=Tu/20. control point takes place; Operating temperature: –5…65 °C;Additional fine tuning of the above para- - “dSt”, the time between two successive (23…149 °F).meters may be tried, keeping in mind how- control point increases (this time is ex- Storage temperature: –30…75 °C;ever the following: pressed in seconds); (–22…167 °F).the “Proportional action” activates the out- - “dSi”, the value, in degrees, of each con- Outputs: two (2) SPST relays 8(3)A 250Vput in direct proportion to the shift in stable trol point increase (a setting of “0” disables AC.system temperature ; this function). Auxiliary output: 12 Vdc/60 mA (forthe “Derivative action” effects the output transducer power supply, e.g. humidityINSTALLATIONdepending on the speed of temperature sensor, pressure transducer, etc.).change; The instrument is designed for flush panel Inputs (depending on model): PTC / RTDthe “Integral action” activates the output in mount. Prepare a 71x29 mm panel cut- (Ni100, Pt100) / Tc (J, K) / 4…20 mAproportion to the continuous integral cal- out; insert the instrument through the front (Ri = 41 Ω).3 EWPC 907 7/2000 ingwhitebluegndinput12 Vdc outResolution: 1 °C (°F) or 0.1 °C (°F). Theright-most digit can also be set to read-outin 0 or 5 only, or in all 10 digits. Accuracy: better than 0.5% of full scale.Power supply (depending on model):12 Vac/dc ±15% or 24 Vac/dc ±15%.DISCLAIMERThis manual and its contents remain thesole property of Invensys Climate Controlss.p.a., and shall not be reproduced or dis-tributed without authorization. Althoughgreat care has been exercised in thepreparation of this document, InvensysClimate Controls s.p.a., its employees orits vendors, cannot accept any liabilitywhatsoever connected with its use.Invensys Climate Controls s.p.a. reservesthe right to make any changes or improve-ments without prior notice.Invensys Climate Controls s.p.a.via dell'Industria, 15Zona Industriale Paludi32010 Pieve d'Alpago (BL)ITALYTelephone +39 0437 986111Facsimile +39 0437 986066Email eliwell@invensysclimate.comInternet http:/www.climate-eu.invensys.com7/2000 ingcod. 9FT40025EWPC 907 7/2000 ing 4

Eliwell EWPC 972 Temperature Control

The EWPC 972 is a micro-processor based digital controller specifically designed for refrigeration systems; it is particularly suited for medium or low temperature range 'forced air' units.

It incorporates three 12 Vdc/30 mA outputs to activate the auxiliary and external relays for (1) compressor, (2) defrost system and (3) evaporator fan control. This instrument must be used with the Din-rail mounted EWDR SLAVE (972 version) module which contains the auxiliary relays; connection is achieved through a compatible MULTILEAD CABLE, equipped on both ends with telephone type quick-disconnect and polarized connectors.

This MULTI-LEAD CABLE conducts all signals, i.e. input signals from the PTC probes, output signals to energize the relays in the module, as well as the power supply to the EWPC 972.

A number of parameters are displayed alphanumerically to set up the EWPC 972 for each specific application.

The EWPC 972 is supplied in the popular '32x74' ELIWELL housing and is manufactured according to VDE and UL norms. The EWDR SLAVE (972 version) is supplied in the 70x85 mm (4 modules) housing for Din-rail (Omega 3) or surface mounting and is manufactured according to VDE and UL norms.

Operation

Eliwell Ewpc 901 T Manual English

Please Note: These are Low Temp Control Setting Instructions for Oscartek Gelato & Ice Cream Showcases

The temperature control is always subject to a positive temperature differential (make on rise): the compressor stops when setpoint is reached and starts again upon reaching the setpoint temperature plus the differential.

A choice of two defrost types is available: electric defrost (during which the compressor stops) or hot gas defrost (during which the compressor is running). Other programming options include: defrost frequency time, time count mode, defrost termination temperature, and a defrost safety limit (time-out).

Eliwell Ewpc 901/t Manual

The evaporator probe is used to control the defrost cycle as well as the evaporator fan: a selection can be made of the temperature above which the fan is OFF, the post-defrost fan delay time and the link between fan and compressor.

A number of compressor short-cycle protection solutions (i.e., delay on start, delay at switching off, delay between two successive starts) are incorporated in the system.

Thanks to a wide selection of other available parameters the controller can be adapted to virtually any application requirement.

Front Keypad

SET: push and release to display the setpoint for 5 seconds.
During this period the 'SET' status light is on and the setpoint can be changed with the 'UP' or 'DOWN' button only.
The system will automatically switch to normal display after 5 seconds upon release of buttons and the new value will be memorized.
UP: used to increase the setpoint value, as well as the parameter when in programming.
When held down for a few seconds, the change rate accelerates.
DOWN: same functions except to decrease a value.
DEFROST: this momentary push button will start a manual defrost cycle whenever it is activated for at least 5 seconds.
Not accessible when in setpoint or parameter programming.
Eliwell Ewpc 901 T Manual
The programmed interval to the next defrost cycle is automatically reset.
The 'DEF' goes on when the defrost is initiated, whether the defrost is manual or automatic.
Led 'COMP': status light of the internalcompressor relay.
It is ON when the compressor is ON.
Led 'SET': it is on during Setpoint display and programming.
It blinks during parameter programming.
Led 'DEF': status light of the defrost.
Eliwell ewpc 901 manual
It is on during automatic defrost; it blinks during manual defrost.

Parameter Programming

Programming is easily accessed by holding the 'SET' button down for more than 5 seconds; the first parameter is displayed while the status light 'SET' remains blinking during the programming period.

Other parameters are accessed with the 'UP' and 'DOWN' button. With the 'SET' button, the actual setting of each parameter is displayed. It can be changed with 'UP' and 'DOWN'.

The system will automatically return to its normal operating mode a few seconds after the programming procedure is completed or interrupted.

Eliwell Ewpc 901 T Manual User

Description of Parameters

diF: diFferential.
Switching differential (histeresis); it will always be set with positive value (make on rise).
LSE: Lower SEt.
This is the lower limit below which the user cannot change the setpoint.
HSE: Higher SEt.
Similar to 'LSE', however setting an upper limit for the setpoint.
dty: defrost type selection.
EL = ELectric defrost;
in = hot gas (reverse cycle) defrost.
dit: defrost interval time.
Defrost initiation frequency in hours.
dct: defrost count type.
dF = digifrost®Feature; defrost starting time ('dit') is calculated based on accumulative compressor running time.
rt = real time; defrost initiation frequency is based on real time. Time between defrost starts is always the same.
SC = Stop Compressor; a defrost cycle is activated each time the compressor stops.
Fr = Free (the compressor relay has no relation with the defrost functions and continues to regulate on Setpoint).
ParameterDescriptionRangeDefaultUnit
diFdiFferential1…152°C / °F
LSELow SEt-99…HSE-55°C / °F
HSEHigh SEtLSE…9940°C / °F
dtydefrost type selectionEL / inELflag
ditdefrost interval time0…316hours
dctdefrost count typedF / rt / SC / FrdFflag
dohdefrost offset0…590minutes
dEtdefrost Endurance time-out1…9930minutes
dStdefrost Stop temperature-70…998°C / °F
FStFan Stop temperature-70…992°C / °F
FdtFan delay time0…9910minutes
dtdrainage time0…990minutes
dPodefrost (at) Power onn / ynflag
ddLdefrost display Lockn / y / Lbnflag
dFddefrost Fan disablen / yyflag
AFdAlarm (and) Fan differential1…502°C / °F
FcoFan compressor offoF / ononflag
cPPcompressor Probe ProtectionoF / onoFflag
ctPcompressor type ProtectionnP / don / doF / dbidoFflag
cdPcompressor delay Protection0…150minutes
odooutput delay (at) on0…990minutes
EPrEvaporator Probe read-out//°C / °F
CALCALibration-20…200°C / °F
tAbtAble of parameters///
doh: defrost offset.
Time delay of defrost start, expressed in minutes.
dEt: defrost Endurance time-out.
Defrost safety limit, in minutes. Defrost cycle is terminated, regardless whether fully completed.
dSt: defrost Stop temperature.
Adjustable defrost termination temperature.
FSt: Fan Stop temperature.
Setting of temperature (measured by the evaporator defrost probe) above which the fan is always OFF.
Fdt: Fan delay time.
Selection of post-defrost fan delay, expressed in minutes.
dt: drainage time.
Upon defrost completion, evaporator fan and compressor remain OFF for this amount of time to allow coil drainage; expressed in minutes.
dPo: defrost (at) Power on.
Selects whether the system should go through a defrost cycle at start-up (or after a power failure).
n = no; y = yes.
ddL: defrost display Lock.
Select whether or not to lock in the actual box temperature display during a defrost.
n = no; during defrost the actual box temperature is displayed.
y = yes; the temperature displayed at the start of a defrost is locked in and does not change during this cycle.
Lb = Label; during the defrost the label 'dEF' is displayed to indicate a defrost is in progress.
Note: with the 'y' and 'Lb' selection, the display remains locked until the box temperature is pulled down again and reaches setpoint.
dFd: defrost Fan disable.
Fan OFF during defrost.
n = no; y = yes.
AFd: Alarm (and) Fan differential.
The allowable temperature swing between ON and OFF of fan functions (see parameter 'FSt').
Fco: Fan compressor off.
The evaporator fan is OFF whenever the compressor is cycled OFF.
oF = yes; on = no.
cPP: compressor Probe Protection.
Select compressor relay status in case of room probe defect.
oF = compressor OFF in case of probe defect.
on = compressor ON in case of probe defect.
ctP: compressor type Protection.
Select the type of (short-cycle) protection best suited for the compressor; the actual delay time is programmed with the next parameter.
nP = no Protection.
don = delay on start; delay applies when relay is energized.
doF = delay at switching oFf. Minimum off cycle time period.
dbi = delay between two successive starts. Limits the number of start-ups per hour.
cdP: compressor delay Protection.
The time delay - in minutes - applicable to the previous parameter 'ctP'.
odo: output delay (at) on.
Time delay - in minutes - applied to activation of the relays after start-up (this parameter is not present on standard models).
EPr: Evaporator Probe read-out.
With this parameter the evaporator temp. can be displayed, even during normal operation.
CAL: CALibration.
Temperature read-out offset to allow for a fixed adjustment up or down due to probe location, if desired.
tAb: tAble of parameters.
This shows the configuration of the parameters as set in the factory; can not be modified (for factory identification and diagnostic purposes only).

Technical Specs

  • Housing: black ABS plastic, self-estinguishing
  • Dimensions: front 74x32mm (2.913x1.260D'), depth 67mm (2.637')
  • Mounting: flush panel moun with mounting bracket
  • Protection: the instrument front panel is waterproof !P65; an optional snap-on cover can be supplied to provide additional protection of the rear terminal block
  • Connections: telephone type receptacle for connection with the EWDR SLAVE module
  • Display: 12.5mm LED (.5D')
  • Push Buttons: located on front panel
  • Outputs: three output signals 12Vdc/30 mA to control the auxiliary relays of the EWDR SLAVE Din-module (compressor, evaporator fan control and defrost)
  • Inputs: two (2) PTC probes for temperature control and defrost termination; these are connected to the EWDR SLAVE module only
  • Resoutions: 1 °C (°F)
  • Accuracy: better than 0.5% of full scale
  • Power supply: supplied by the EWDR SLAVE

Installation

Eliwell Ewpc 901 Manual

The EWPC 972 is designed for flush panel mounting. Insert the unit through a 29x71mm panel cut-out and affix with the U-bracket supplied.

The EWDR SLAVE (972 version) is designed for surface mounting (pull out both lugs) or for Din-rail mounting (Omega 3). Connection between these two units is achieved through a compatible MULTI-LEAD CABLE, equipped on both ends with quick-disconnect and polarized connectors.

The ambient temperature around the instruments should be kept between –5 and 65 °C (23…149 °F); select a location which will not be subject to high humidity or condensation.

Allow some ventilation to provide cooling to the EWPC 972.

Electrical Wiring

The EWPC 972 has a telephone multi-lead connector for the Din-rail mounted EWDR SLAVE module.

Eliwell Ewpc 901 T Manuals

The EWDR SLAVE (972 version) module - aside from the telephone connector for the EWPC 972 - has two screw terminal blocks (2.5 mm2; one wire each terminal only, in compliance with VDE norms) for the remaining electrical wiring.

Make sure that the power supply to the EWDR SLAVE corresponds with the rating shown on the instrument. The two 2-lead PTC probe cables do not require polarity and can easily be extended by using regular 2-lead stranded wire.

It is strongly recommended to run the probe cable and the MULTI-LEAD CABLE separate from line voltage wiring. Also, it is good practice to install the tip of the probe in upright position, to avoid moist from entering into the stainless steel sensor housing.

Error Messages
Eliwell

The EWPC 972 causes the display to read 'E1' in the event of a problem with the box probe. This could mean: either an open or shorted sensor, sensor not connected, temperature 'under range' (below –55 °C or –67 °F) or temperature 'over range' (over 99 °C or 210 °F).

An error reading 'E2' means a problem with the evaporator probe.

It is recommended to double-check the sensor wiring before diagnosing a probe as defective.